GLOW is a three-component research blend: GHK-Cu 50 mg, BPC-157 10 mg and TB-500 10 mg in a single 70 mg vial. Three molecules in one container is a different analytical object from three vials, and the differences are not obvious from the label. This guide covers what is actually in the vial, the molar arithmetic the mass figures hide, and what a three-component Certificate of Analysis has to show.
SOMA Research supplies GLOW for laboratory research use only. It is not a drug, supplement, food or cosmetic, is not approved by the FDA for any use, and is not intended for human or veterinary consumption.
The three components
| Component | Mass | Molecular weight | What it is |
|---|---|---|---|
| GHK-Cu | 50 mg | ~403.9 g/mol | Copper tripeptide-1 — a peptide–metal complex |
| BPC-157 | 10 mg | ~1,419.5 g/mol | 15-residue gastric protein fragment |
| TB-500 | 10 mg | ~889 g/mol | Acetylated LKKTETQ, a thymosin β4 fragment |
Each has its own guide; the BPC-157 and TB-500 guide covers the latter two together, including the naming ambiguity around what “TB-500” refers to.
The mass ratio is not the molar ratio
This is the single most useful thing to understand about any blend, and GLOW makes it unusually stark because its components differ in molecular weight by more than threefold.
By mass, the vial is 71% GHK-Cu and about 14% each of the other two. By moles — which is what determines how many molecules of each are present, and therefore what a concentration means in any experiment — the picture shifts substantially:
| Component | Mass | By mass | Amount | By moles |
|---|---|---|---|---|
| GHK-Cu | 50 mg | 71.4% | ~123.8 µmol | 87.1% |
| TB-500 | 10 mg | 14.3% | ~11.2 µmol | 7.9% |
| BPC-157 | 10 mg | 14.3% | ~7.0 µmol | 5.0% |
| Total | 70 mg | ~142.1 µmol |
So the vial contains roughly seventeen GHK-Cu molecules for every one of BPC-157, against a mass ratio of five to one. Equal masses of BPC-157 and TB-500 are not equal molar amounts either — there are about 1.6 TB-500 molecules per BPC-157.
Figures above are calculated from the stated composition and the published molecular weights, before any correction for salt content; the lot CoA’s peptide-content figures refine them. Nothing here says anything about what the blend does — it is arithmetic, and it is the arithmetic any dose-response calculation has to start from.
What the copper changes
GHK-Cu is not simply the largest component by mass; it is the only one that is a metal complex, and that brings constraints the other two do not.
- No chelators in the buffer. EDTA, EGTA and citrate strip copper from the complex, converting GHK-Cu into free GHK plus a copper–chelator species. In a blend this quietly changes one of three components into something else while leaving the other two untouched.
- Colour is a free diagnostic. The copper complex is blue to blue-violet and it dominates the vial by mass, so a GLOW preparation should carry visible colour. Loss of it in a stored solution indicates the copper complex has not survived — the other two components give no such signal.
- pH range is set by the most fragile component. The copper coordination depends on backbone amide deprotonation and is pH-sensitive; the two peptides are comparatively tolerant. The blend therefore has to be kept within the narrower window GHK-Cu needs.
- One favourable coincidence. Copper(II) is redox-active and can catalyse oxidation of susceptible residues. None of BPC-157 (GEPPPGKPADDAGLV), TB-500 (LKKTETQ) or the GHK tripeptide contains methionine, cysteine or tryptophan — the three residues that oxidise most readily. The usual metal-catalysed oxidation concern therefore has little to act on in this particular combination.
Reading a three-component CoA
Everything that makes a two-component certificate harder to read applies more sharply here.
- A single purity percentage cannot describe three molecules. It may mean each component separately, or all three summed against everything else. A complete certificate resolves and reports each.
- Ratio is a separate measurement from purity. Three components can each be individually pure and still be present in the wrong proportions. Purity says what fraction is not impurity; it says nothing about how much of each intended component is in the vial.
- Expect three masses. Approximately 403.9, 889 and 1,419.5. Fewer than three on a three-component blend is an incomplete report.
- Chromatographic resolution deserves checking. GHK-Cu is small and highly polar and elutes early on reversed phase; the two peptides are larger and more retained. The components should separate, but a metal complex does not always chromatograph like a plain peptide, and a method that handles peptides well may handle the copper species poorly. Confirm three resolved peaks rather than assuming them.
- Which species was measured for GHK-Cu. The free tripeptide (~340.4) and the copper complex (~403.9) give different masses. A certificate that reports a mass without naming the species leaves the central question about that component open.
Our Certificate of Analysis guide covers the individual fields; measured figures per lot are published in the CoA library.
Handling and storage
- Lyophilised powder: -20°C, protected from light — required by the copper component, not optional here.
- Reconstituted stock: 2–8°C, aliquoted, used within approximately 30 days.
- Avoid chelating agents and reducing agents in any buffer, for the reasons above.
- The ratio is fixed. All three dissolve together and cannot be separated on a normal bench, so every aliquot carries the vial’s proportions. Work needing the components independently must source them independently — GHK-Cu and BPC-157 are listed separately.
- Avoid freeze-thaw cycling.
Procedure and concentration arithmetic — which for a blend must be done per component — are in our reconstitution guide.
Related guides
Research use only
Research-grade GLOW is supplied for laboratory use by qualified researchers and institutions. It is not manufactured to pharmaceutical standards, has not been approved by the FDA for any use, and must not be used in or on humans or animals. Nothing in this guide is medical advice or a representation that any component is safe or effective for any purpose.